pci-7344. 75 ms corresponding to 180 degrees. pci-7344

 
75 ms corresponding to 180 degreespci-7344  In this Pin No 5 and Pin No9 are PWM1 and PWM2 respectively

Options. Because I have two motion control systems (PC with 7344 and MID7654 controlling 3 axis servo system) I decided it was best to . The PCI 7340 (4 axis) board is a drop in replacement for the PCI-7344. また、NIのホームパージから. 10-27-2001 03:20 PM. Periodically the servo system does not work. We built the entire machine to industrial standards for ruggedness, reliability, and minimal down time. Please let me know if you have any additional questions on this issue. Hi, Is there any body to have controlled torque with PCI-7344? I have two servos to keep servo's torque constant as a target value. 445 subscribers. National Instruments PCI-7344 Motion Controller Device. supoose in my . Attention! Your ePaper is waiting for publication! By publishing your document, the content will be optimally indexed by Google via AI and sorted into the right category for over 500 million ePaper readers on YUMPU. I have 7330. The secret is getting the correct Parker-Compumotor Gemini cable that plugs into the GV's 50 pin drive. 5をインストールし、PCI-7344を正常に認識しました。Motion Assistant 1. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. NI-DAQmx. A National Instruments PCI-7344 4-axis controller card that resides in a PCI slot in a Windows PC controls motion. Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. PXI-7344 PXI/CompactPCI PCI-7344 PCI FW-7344* IEEE-1394 * Windows 2000/Me/98 only. The pulse should last from 1. 240 MHz signal. It offers linear interpolation for coordinating multiple axes, real-time system integration for directly communicating with data acquisition or image acquisition hardware, and high. (67 pages) Controller National Instruments sbRIO-9607 User Manual. . I encountered problems controlling the motor with MAX using a digital signal. comHi,All I use NI PCI-7344,UMI-7764 and servo motor in my project. Page 3 Sweden 08 587 895 00, Switzerland 056 200 51 51, Taiwan 02 2528 7227, United Kingdom 01635 523545 For further support. Mid-Range Stepper/Servo Motion Controllers 2 AMC GmbH Chemnitz * Tel: 0371/38388-0 * Fax: 0371/38388-99 * [email protected] PCI-7344 with LabView for use as a Parabolic Antenna controller. Sacha, with the built in controller all you have to do is to wire a serial cable to the serial port of your PC and the drive and use VISA functions to send ASCII commands to the device. 7350 and 7340. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and. 0 and PCI-7344 motor. Current PC config is: Pentium 4 - 2. The PCI‑7344 also provides contouring capability for complex moves. I have no choice in using synchro's as feedback. 通常でしたらバージョンアップのLabVIEWのCDと別にドライバCDも付属されているはずです。. Unfortunately the output pulse has a length of about 20 ms and so I have to decrease the speed of my stage rapidly (otherwise the. eBay item number: 293975447283. 13 NI FP 2000 Hardware Platform Set up 41 3. jspaarg. 10-02-2007 06:58 AM. 445 subscribers. 1, FLEX MOTION 5. all controllers in the 7344/7334 family. The PCI‑7344 also provides contouring capability for complex moves. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. As the second option requires three axes, at least a PCI-7344 is required for this method. A NI PCI-6527 48-bit digital I/O board that resides in another PCI slot inside the PCHello, I am trying to find out what type of switches will work with PCI-7344 (4-Axis Stepper/Servo Controller for PCI) limit and home inputs. Use a lower resolution stepper motor. I am using LabVIEW 2014 and NI PCI 7344(motion controller). 付属されていた新しいドライバCDはインストールしましたでしょうか?. 2. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. Hi, I am using a PCI-7344 with a UMI-7764 to try and control 3 linear actuators and 1 semi-rotary actuator, each of these actuators takes a 0-10v dc voltage and has a feedback signal of 0-10v dc, both input and output being proportional to linear/angular displacement. If you have non-plug and play (ISA bus) boards, refer to the ISA Installation (PC-FlexMotion-6C Only) section of this document. Servo motors expect a pulse every . Options. Summary of Contents for National Instruments 7344 Series. Is it possible to realize such a sample rate with breakpoints and an onboard program like: "Modulus Breakpoint (on-board re-enable). The driver circuits convert TTL level signals for four axes to the ±12 V highconjunction with National Instruments’ PCI-7344 motion controller card and UMI-7764 terminal block. The 7342 follows this position profile using a spline algorithm. 我目前的系統是PCI-7344 + UMI7764 LabVIEW 8. 3. 1 asks for firmware upgrade. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. g. Re: PCI-7344 motor interfacing help. Re: PCI-7344 motor interfacing help. 2 + NI motion 7. The PCI‑7344 also provides contouring capability for complex moves. If you select the Firmware tab, there should be a button near the top of the screen callled "Update Firmware" If the firmware is up to date, it will be grayed out. 1 (NIMotion7. Solution Accepted by topic author domarm Re: Compatibility of PCI-7344 on WIN10 TSE_Expert NI Employee (retired) 06-13-2019 03:04 AM Options Hi Martin, yes it. 1 Release Notes 4 ni. On the other hand please take into account that the PID loop is running much faster and in order to align the trajectory generation rate ( = 10 ms in contoured mode) and the PID rate (= up to 62,5 µs) the DSP is calculating interjacent setpoints at the rate of the. e. . C74B552B@univ-valenciennes. NATIONAL INSTRUMENTS NI-PCI-7344. I recently upgraded to MAX version 2. The PCI-7344 is a motion control board that requires the NI-Motion driver software. 您可以按照以下步骤配置运动控制器并测试步进电机:. Product Manuals: 7344/7334 Hardware User Manual Products & Services: National Instruments Motion Control NI Motion: Users Manual 附件: 报告日期: 10/03/2002 最近更. I've never used LabVIEW 6. The 7342 follows this position profile using a spline algorithm. I initialise it using NI MAX (version 2. I am able to get a nice response c. Hello, I am using a PCI-7344 motion controller card to drive 2 stepper motors in closed loop mode. Lai Wechat:17750010683 Whats app:+86 17750010683 Skype:+86 17750010683 QQ: 3221366881 [email protected] there, I would like to trigger my piezoelectric motor more than 100Hz, can I do that with motion controller PCI-7344/PCI-6036E and using while Return to Home Page Toggle navigationThe PCI-7342 / 7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. ) Issue: W. When calling "DIO Port Config. 00 +$12. i finally start to understand the setting after i read the PCI7390 which is position-comannd controller. . . The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. The first two axis (#1 and #2) both work fine. I. Running the motor is not a problem but when it has stopped (there is no load) the servo system still puts out a lot of voltage (+-48V) all the time. something) Thanks - raymond. dll well with vc,but when I use it under rtx ,it does not work,appering " can not load the driver". Looking to measure speeds up to 500 RPM. いつもお世話になっております。 daqの外部クロック読み込みについて質問があります。 現在、pci-7344およびpci-7764を用いて、サーボアンプからのエンコーダ信号を読み取り、この信号を外部クロックとして、pci-6221に入力する電圧を読み取りたいと思っています。Im using a UMI-7774 and a PCI-7344 motion controller with a Compax C3 servo drive. flx) to trigger a move (Start Motion. Options. The PCI‑7344 also provides contouring capability for complex moves. controller in the 7344 family and contains information concerning their operation and programming. I have one 3 axes(X,Y,Z) mchine. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. IIssue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. "The polarity of the trigger input is programmable in software as active-low (inverting) or active-high (non-inverting), rising or falling edge. 00 shipping And i want to connect it to UMI-7774 with PCI-7344 also configured in MAX to work in P-Command mode. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. Fast Quotes & Shipping. vi twice for both the Hardware and Software limits. . Mark as New;. 1) How do i know if this motor drive is compatible with the pci-7344 and umi7774 ? for example: inside the UMI manual is written that the Motor drive must support "Sinusoidal Commutation" i. Unless otherwise noted, text applies to all controllers in the 7344 family. In Windows Device Manager, right-click on the PCI Simple Communications Controller and select Properties . I've created a program that uses motion control and digital I/O via the PCI-7344 Motion Control card. I would like know if PCI-7344 Stepper/Servo Motion Controller performs electronic camming. If you are upgrading from a previousHi, How do you reset the encoder count on a servo motor without reseting the position of the motor itself? "Reset encoder count" VI doesn't work. The third axis (#3) is counting properly but not finding the index. 6: Cấu trúc của máy phay CNC. 32. . Page 2 Motion Control 7344/7334 Hardware User Manual 7344/7334 Hardware User Manual May 2001 Edition Part Number 322504B-01. The PCI Security Standards Council helps protect payment data through industry-driven PCI SSC standards, programs, training, and lists of qualified. There does not appear to be any built-in support for that device. Re: LabVIEWアップデートに伴うPCI-7344のエラー. I am using four amplifiers; three are on linear motors, one on a ball screw. Shut down your computer. freedesktop. We used NI vision (IMAQ PCI-1409), motion controller (PCI-7344), and DAQ (PCI-6025E) cards for this MPVIEW. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. Best regards, Jochen Klier. 12-10-2002 05:13 AM. 7)and NI-DAQ 7. We have a drive which sometimes needs manual adjustment, so we have to turn off the torque, i. 75 ms corresponding to 180 degrees. In your vi you are using Start Motion all the time. Because of the reason mentionned in the link in my first mail, I doubt that a calibration certificate exists for this card. 08-10-2007 01:26 AM. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. 4-Axis, Stepper PXI Motion Controller Module. In the Stepper Settings tab (near the bottom of the screen), select your Stepper Steps Per Revolution, Stepper Loop Mode, Stepper Polarity, Stepper Output Mode, and Pull-in Tries. [posted and mailed] christelle. Without seeing the program, it's impossible to tell but execution highlighting and single step mode changes the way the program executes and. PCI-7344を他社製のモータードライバに接続しようと思います。モータードライバのパルス入力の仕様で、パルス幅が10μSec以上となっているのですが、PCI-7344を接続して使うことはできますか?Using a PCI 7344 and three servos (with LabVIEW). PCI-7390 Driver. . . I have one 3 axes(X,Y,Z) mchine. Hi all, I'm using the output pins of the 7344 - board. I am already using one. PCI-7344. Work with our experts to sustain your critical applications. Why would the Blend Complete bit get set rather than. I would appreciate if you can suggest me any research that I could do on this system which involve 3 axes motion -using all ac servo motor (automated storage and retrieval system) - I. I would also appreciate one for the Video Capture Board PCI-1409. 75 ms. Does this give you any clues? So you are saying this is a bug which was fixed with a patch in earlier LV versions? I didn't find any documentation on this. Under windows system I use the flexmotion32. Dennis_Knutson. The 7334 controllersThe solutions that I have proposed are of course much more complex than using a PCI-7344 motion controller as all the software layers that are present in the firmware of the PCI-7344 need to be implemented in software. The step/ direction signals from the controller card are converted to phase-drive signals using three UCN5804B stepper ICs, one for each axis, and routed through a 25-pin D-subminiature connector cable to the MAXNC-10. Go to the Axis Configuration option, under the desired axis (e. Not all NI Motion controllers can control a step motor, but the following can: PCI-7332, PXI-7332, PCI-7334, PXI-7334, PCI-7342, PXI-7342, PCI-7344, PXI-7344, PCI-7352, PXI-7352, PCI-7354, PXI-7354, PCI-7356, PXI-7356, PCI-7358, PXI-7358, and PCI-7390. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. Due to a large instal. flx with a PCI-7344 motion controller to gather velocity data from 3 axes at 333Hz for about 4 seconds. PCI-7344 National Instruments PCI-7344 National Instruments Module Clips Drive controller servo motor Contact: Mr. 2) I manaully turned a motor and read back the positions through 1-D Interactive are between arou. I use Windows NT4 and Labview 6. Now I have used to VI PWm duty and config PWM. I have verified the connection is working. NI 7330 NI 7332, NI 7334. I encountered problems controlling the motor with MAX using a digital signal. flx, but i don't know how to wire it. 10 NI UMI 7765 Universal Machine Interface Card 38 xu . About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. I know there is in flexmotion library the : Initialize controller. Depending on the movement of a xy - stage (controlled by the motion controller) I'd like to trigger a laser pulse. The National Instruments PCI-7342 / 7344 also provides contouring capability for complex moves. Lai Wechat:17750010683 Whats app:+86 17750010683Hello, I am fairly new to LabVIEW and was wondering how to implement incremental rotary encoders into a motion control VI. Right now, the +5V pins connected through an amplifier board to the "Host +5V" pin#59 in Motion I/O Connector of PCI-7344 board. Shut down your computer. This is one of true pains of maintaining legacy systems. I am using LabVIEW 2014 and NI PCI 7344(motion controller). It takes 10-20 milliseconds to start the move after the trigger. 0 system with the newest NI-Motion 7. The FW-7344 is only compatible with LabVIEW versions earlier than LabVIEW 8. Depending on the movement of a xy - stage (controlled by the motion controller) I'd like to trigger a laser pulse. The 7334 controllers are exclusively stepper motor controllers. The PCI-7344 motion controller card also included analog and digital outputs, which we use to control the spray nozzle, the gas flow valve, the multi-port solenoid valves, and the fan. The 3 axes operate together in contouring mode. The Motion driver with the PCI 7344 has its own algorithm in place. The problem now is: I am not able to wire blocks and delete blocks in the block. . Find many great new & used options and get the best deals for National Instruments PCI-7344 Servo Controller Card at the best online prices at eBay! Free shipping for many products!Re: LabVIEWアップデートに伴うPCI-7344のエラー. Warranty Terms and Conditions. 0 and NI-Motion 7. i then use MAX to communicate with the drive. However, when the Software limits are reached, the. 付属されていた新しいドライバCDはインストールしましたでしょうか?. hwdb hwdb/20-usb-vendor-model. From troubleshooting technical issues and product recommendations, to quotes and orders, we’re here to help. PCI/PXI/FW Installation Complete the following steps to install your PCI/PXI/FW motion controller: 1. In addition, a PCI network card connects this MPVIEW to the Internet through the local area network (LAN). Fault+. Re: Position Control of compumotor linear servo table and GV-U6E with PCI-7344. Overview of the 1-D Interactive Panel. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. Servo motors expect a pulse every . 288. The PCI-7334 is the NI low-cost stepper-only motion controller, which offers the flexibility and ease-of-use features found throughout the FlexMotion line of controllers. 0 and earlier. PCI-7390 Driver. Options. NI-Motion Issue Details I can command my motion controller to move a stepper motor to a target position in Open Loop mode, but when I configure it to run in Closed Loop mode, the motor doesn't appear to complete the move, doesn't move at all,. The 7344/7334 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 • PCI-7334 The 7344/7334 controllers are designed for PCI, PXI, and 1394 bus computers. The recent patches for the PCI-7344 card helped our speed problem but not this one. This compatibility allows the computer to automatically perform all bus-related configuration and requires no user interaction. Options. If you are installing a PCI or PXI controller, install the controller in an available slot in your computer. Bgrain, there is no way to tweak a PCI-7344. Knight of NI. . The PCI‑7344 also provides contouring capability for complex moves. Options. About the 7344/7334 Controller The PCI/PXI-7344/7334 and FW-7344 controllers feature advanced motion control with easy-to-use software tools and add-on motion VI libraries for use with LabVIEW. can we get the VI for oscillator with variable frequency from 10 khz to 1 Mhz with variable duty cycle. I don't see a good way to control 5 motors with this board. Hope this helps, Jorge M. Hi, I updated my PCI-7344 + LabView 7. Hi all, I'm using the PCI-7344 board and I'd like to trigger an external device. The 7344 controllers are warranted against defects in materials and workmanship for a period of 1 year from the date of shipment, as evidenced by receipts or other documentation. The onboard CPU uses an embedded real-time OS. FlexMotion 5. I have 3 ORIEL motors (Model: 18277, 18215) to drive an x-y-z station. Trouble with motion control because of encoders. . If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. As the control loop is typically running much slower on the FP system compared to the PCI-7344, you will have to modify the PID parameters accordingly. 3-Axis control, stepper motors, closed loop with optical linear encoders. All of 3 motors require +5V 24mA for the Mike encoder. I encountered problems controlling the motor with MAX using a digital signal. Re: PCI/FW-7344 Motion controller either isn't found or when it is, MAX crashes depending on which version of NI-Motion, DAQ and. 1 asks for firmware upgrade. Member. Right-click on PCI Device and select Uninstall. The indexes are offset from each other. The pulse should last from 1. Each axis uses 2 Synchro's (1:1 & 36:1 for Course & Fine 90V / 60Hz) for feedback. (The servo drive manual is here:The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. de * Technical Support for Motion SoftwareI'm not sure what you mean by voice coil, but the UMI 7764 is designed to interface with third party amplifiers to drive motors. 10-27-2001 03:20 PM. fr>: >Hello, >I've got a PCI card (PCI 7344 for motion control). lexmotion PCI-7344 with LabView for use as a Parabolic Antenna controller. I am using a PCI-7344 card with LabView to control a 3-axis servo motor motion system in conjunction with a data acquisition system. In the second part, you program for the PCI-7344 controller, which adds several advanced features including the ability to run onboard programs. ) angle. If it's possible to update your application to LabVIEW 2015+, my company has a replacement solution for PCI-7344. Regards, Shut down the system and physically remove the PCI-7344 from the system (important to remove resource locks). But i >want to do it automatically in a VI. Giridhar, everything is ok with your 7344. PCI-7344 was listed as an obsolete card already. Indeed, when we use a newer PCI7344 card, we have driver / firmware compatibility issues. Motion Control Module This article will show you how to test motor functionality. 像是PCI-7344的STEP馬達要設定成position mode,而servo馬達要設成velocity mode這類的。而關於PCI-7344的設定值怎麼設定,. baseaddresses[0] is the base-address of the miniMITE and I can get the vendor ID, device ID by directly reading from baseaddresses[0] +offset,but baseaddresses[1] does not like. はじめまして。投稿させていただきます。 現在、PCI-7344とUMI-7764を用いて3つのACサーボモータを速度制御しようと考えています。 用いるサーボモータとアンプはそれぞれ、三菱電機製のHC-KFS13と、MR-J2S20A1です。 初歩的な質問をして申し訳ないのですが、アンプとUMI-7764の結線の方法がわかりませ. Applications Engineering Group. You can select certain frequencies for the PWM which correspond to the divided down 10. Trusted Seller. Lai Wechat:17750010683 Whats app:+86 17750010683The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. PCI 7344 card. At Lektronix we can provide you with a brand new National Instruments PCI-7344 covered by the Original Manufacturers Warranty. I have just completed the cable that connects the amplifier to the encoder. Commands and their parameters can be stored in an onboard. The PCI‑7344 also provides contouring capability for complex moves. FlexMotion 5. I would like to implement the same thing using FP & Softmotion instead of 7344 board as later I would like to implement fuzzy logic control into softmotion. The 7344 can do a frequency of 40 Hz or 78 Hz (which either. 08-10-2007 01:26 AM. 579 views 3 years ago. 11-09-2010 03:33 PM. 09-27-2002 08:03 AM. If you are upgrading from a previousI am using PCI7344 and UMI7774 to do simple control of a motor to make certain movements. Features The 7344 controllers are a combination of servo and stepper motor controllers for PCI, PXI, and 1394 bus computers. But the MAX couldn't read the current traject. 6 on a separate desktop system with a PCI-7344 motion controller and a PCI-6221 DAQ card. 1. Using the X-Y Grid Inspection (Template). Dennis_Knutson. In MAX under NI-Motion select your PCI-7344. 01-30-2006 10:29 AM. How do I do that? Hopefully, there is also a way for me to h. So the servo's torque reaches the target, it shoud be stopped at that postion unless any change in servo's torque happens. When I set it up with the Ni-7344 the drive is ready (green led on drive flashes). This was a problem at first, because the amplifier is intended for differential outputs, while my encoders have single. We used thirty-five digital I/Os for a variety of purposes, including safety interlocks, proximity switches, and optical sensors. MPN. The PCI‑7344 offers blended motion trajectory control and fully coordinated circular, linear, point‑to‑point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. To research general control behavior this might be ok but if you want to use FieldPoint in a real-world application you should figure out if the PID loop is fast enough for you. Hi, I use PCI-7344 and UMI-7764 and upgrade the motion software and firmware to 7. The onboard CPU uses an embedded real-time OS. option from the right-click menu. 4-axis, step / servo PXI motion controller module - pxi-7344 is suitable for both simple and complex motion applications. . We have been trying to control the velocity and position of our servomotor but regardless of what values we put in the motor always moves at about 500 rpm and travels about -31000 cnts before stopping. I need to be able to read the RPM of an encoder. また、NIのホームパージから. umi-7764/7774をステッピングモーターメーカーのモータードライバに接続して使おうとしています。モータードライバはフォトカプラ入力になっています。どのように接続したらいいですか?From MAX, select your PCI-7344 under NI Motion Devices. All the best-John05-14-2002 08:10 AM. TheSee all Driver Software Downloads. I'm testing angle sensors whose voltage output is proportional to (you've guessed it. Any help is appreciate. This controller is designed for PXI, PCI, and 1394 bus computers. No worries Chris. I'm trying to write the program in LabView to respond after the E-stop button is release. The 10 ms timing for contoured move is the fastest that you can get out of the board. >I initialise it using NI MAX (version 2. This motion controller can control upto 4 servo motors and can give 2 PWM signal. 10-02-2007 06:58 AM. So I wonder if there is driver u. The NI Motion drivers with the 7344 motion controller are not capable of that type of control. An introduction to the National Instruments PCI-7344 Motion Controller Featured with 3D contouring, 3D linear and circular interpolation, and up to 62 ms. The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. 0 and NI-Motion 7. The 7344 family of controllers includes the following controllers: • PCI-7344 • PXI-7344 • FW-7344 The 7344 controllers are high-performance controllers for PCI, PXI. 75 ms. A National Instruments PCI-7344 4-axis controller card that resides in a PCI slot in a Windows PC controls motion. 我使用的硬件是PCI-7344,UMI-7764,Sanyo 伺服驱动器和伺服马达一套 运动控制卡的驱动是NI-Motion7. All the best-John05-14-2002 08:10 AM. Restart and uninstall NI-Motion and Measurement & Automation Explorer (MAX) using the Add/Remove Programs Applet in the Control Panel. return to the previous setup which has NI-Motion 6. Re: problems with a PCI-7344 motion controller. The target torque can be changed on cerain conditions. Re: problems with a PCI-7344 motion controller. I have a PCI 7344 connected to a UMI and a Ecodrive amplifier, with a linear modul and servo. After I issue an absolute move on a closed loop stepper axis with PCI-7344 using flex_Start, the Move Complete bit never gets set, but the Blend complete bit does. Support Worldwide Technical Support and Product Information ni. 3. If yes, then how to configure the other one, so. . We are looking for an old PCI 7344 card (4 axis card driving motors) over 15 years old (copyright 2001). If you are installing the FW-7344, connect the controller to your computer’s IEEE-1394 port. Problem 1 The encoder counts up and down ok but gives 4096 counts between z pulses and not 1024. 1) connected to a MID-7604 drive to control three IDC P21T stepper motors. It works fine in the LabVIEW environment but ignores does not perform any action that uses the motion card. Is there any way to change the velocity while still col. Allen C. Re: a problem with Flex-6C controller MarcoPolo5. Martin Issue Details I have a PCI-7344 with a UMI-7774 and a Yaskawa Servo Motor and Driver. 在 配置面板中 ,展开 我的系统 树. The change was part of an improvement to the manufacturing process for. Send. Page 1 PCI-7334. I make apply the parameters followed by the stage Initialisation and the motor is. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. 7)and NI-DAQ 7. 0. In the Details tab, when selecting the "Device instance path" or "Hardware Ids" Property, there should be an entry similar to PCIVEN_XXXX&DEV_XXXX&. zip" has been downloaded 223 times with a user rating of 5 out of 5 stars, based on 10 reviews. After this software upgrade, several things changed. 1 Release Notes 4 ni. The Problem is feedback from each axis (AZ & EL). The PCLK (or Pulse Clock) line can also be used to input your own clock which is divided down by 256 or 32,768 depending on what you select in. While this is happening, I need to change the velocity of one of the motors. 190976A-04. . The PCI-7342 / 7344 offers blended motion trajectory control and fully coordinated circular, linear, point-to-point, gearing, and vector-space control in either embedded motion operation or host-centric programming environments. WindowsXP system put it as unknown PXI-4200 board. I'm programming a 3-axis piezo stage to do fast scanning (128x128 points in ~ 5 seconds) with a PCI-7344. 8 Ghz, 4 Gb Ram, Matrox Pahelia Video card (agp), PCI-7344 and FW-7344 (Firmware version 6. It is related to 3D printer. Cary, NC,. used. NI-VISA. Here is a link to a feature comparison table for all. I am usi. Hi all, We have a testing machine with three stepper motor actuators. So I wonder if there is driver u. I've been using NI, PCI-7344 motion controller. The PCI‑7344 includes dual processors, a real-time onboard OS, and multiaxis interpolation. The PCI‑7344 also provides contouring capability for complex moves.